Exact manual only
Pit Boss PB850M error codes and icons
This page applies to the Navigator 850 Connected Grill PB850M. Its connected controller uses `Err` plus a flashing component icon; the icon is part of the diagnosis.
What this exact manual documents
ErHOverheat error
- Manual meaning
- The manual identifies an overheated unit, possibly due to a grease fire or excess fuel.
- Safe first move
- Hold Power for the documented shutdown, let the grill cool, then complete maintenance and component-position checks before restarting.
ErPGrill-probe connection error
- Manual meaning
- The grill-probe wire is not making a connection or the grill probe is broken.
- Safe first move
- After full cool-down and disconnection, use the model manual to inspect the grill-probe connection. This code is not PB260PSP2’s power-outage lockout.
ErLStart-up or flame-stability error
- Manual meaning
- The grill fails to perform its start-up cycle or will not stay lit.
- Safe first move
- Once cool and unplugged, check component placement, fuel, feed obstruction, grill-probe condition, and fan behavior through the model manual before another start.
NoPMeat-probe port error
- Manual meaning
- The meat-probe connection port has a bad connection or the meat probe is damaged.
- Safe first move
- Reconnect the meat probe at the control-board port and inspect the adapter end and wire. This is a food-probe message, not a cooker sensor fault.
Err + flashing auger iconAuger feed or connection alert
- Manual meaning
- The auger motor is jammed or not making a connection.
- Safe first move
- Cool and unplug before touching the feed system. Confirm whether pellets are dropping into the burn pot before treating the motor as failed.
Err + flashing igniter iconIgniter function or connection alert
- Manual meaning
- The igniter is not working properly, is not making a connection, or has failed.
- Safe first move
- Let the grill cool completely and use the manual’s check before considering a replacement. Do not order an igniter from the code and icon alone.
Err + flashing fan iconFan function or connection alert
- Manual meaning
- The fan is not working properly or is not making a connection.
- Safe first move
- Cool and unplug before inspection. Use the model manual’s airflow and wiring check rather than treating this as a universal fan diagnosis.
Err + flashing pellet iconFuel quality or feed alert
- Manual meaning
- The manual identifies lack of fuel, poor fuel quality, or a grill that will not stay lit.
- Safe first move
- After cooling, check hopper level and remove damp or poor-quality pellets before treating the auger or controller as the cause.
Sources consulted
- Pit Boss: PB850M Owner’s Manual opens in a new tab (manufacturer doc; checked 2026-08-12)